Single Phase Solid State Relays Series: 1 SJ/K |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
| DC CONTROL |
| Control voltage range |
|
4-32 |
4-32 |
4-32 |
4-32 |
Vdc |
| Control current range |
|
8-30 |
8-30 |
8-30 |
8-30 |
mA |
| Pick-up voltage |
|
4-0 |
4-0 |
4-0 |
4-0 |
Vdc |
| Drop-out voltage |
|
1-0 |
1-0 |
1-0 |
1-0 |
Vdc |
| Input resistance |
|
Current regulator |
|
| OUTPUT |
| Mains control voltage |
VRMS |
24-240 |
24-240 |
24-240 |
24-240 |
Vac |
| Repetitive peak off state voltage |
VDRM |
600 |
600 |
600 |
600 |
Vpk |
| RMS on-state current |
IT |
10 |
16 |
25 |
40 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| On-state voltage drop |
VTM |
1.6 |
1.6 |
1.6 |
1.6 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
10 |
10 |
10 |
10 |
mA |
| Peak one cycle surge current (non-rep) |
ITSM |
100 |
160 |
500 |
500 |
A |
| Holding current |
IH |
50 |
70 |
120 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
200 |
200 |
200 |
200 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
2 |
1.6 |
1 |
0.85 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Operating temperature |
TO |
-30 to +80 |
-30 to +80 |
-30 to +80 |
-30 to +80 |
°C |
| Turn-on time |
T-on |
10 |
10 |
10 |
10 |
ms |
| Turn-off time |
T-off |
10 |
10 |
10 |
10 |
ms |
| Fusing current |
I2t |
50 |
128 |
1250 |
1250 |
A2s |
Single Phase Solid State Relays Series: 1 SJ/K |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
| DC CONTROL |
| Control voltage range |
|
180- 280 |
180- 280 |
180- 280 |
180- 280 |
Vac |
| Control current range |
|
9-18 |
9-18 |
9-18 |
9-18 |
mA |
| Pick-up voltage |
|
180 |
180 |
180 |
180 |
Vac |
| Drop-out voltage |
|
45 |
45 |
45 |
45 |
Vac |
| Input resistance |
|
Current regulator |
|
| OUTPUT |
| Mains control voltage |
VRMS |
24-240 |
24-240 |
24-240 |
24-240 |
Vac |
| Repetitive peak off state voltage |
VDRM |
600 |
600 |
600 |
600 |
Vpk |
| RMS on-state current |
IT |
10 |
16 |
25 |
40 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| On-state voltage drop |
VTM |
1.6 |
1.6 |
1.6 |
1.6 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
10 |
10 |
10 |
10 |
mA |
| Peak one cycle surge current (non-rep) |
ITSM |
100 |
160 |
500 |
500 |
A |
| Holding current |
IH |
50 |
70 |
120 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
200 |
200 |
200 |
200 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
2 |
1.6 |
1 |
0.85 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Operating temperature |
TO |
-30 to +80 |
-30 to +80 |
-30 to +80 |
-30 to +80 |
°C |
| Turn-on time |
T-on |
40 |
40 |
40 |
40 |
ms |
| Turn-off time |
T-off |
80 |
80 |
80 |
80 |
ms |
| Fusing current |
I2t |
50 |
128 |
1250 |
1250 |
A2s |
Single Phase Solid State Relays Series: 1 SJ/K |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
| DC CONTROL |
| Control voltage range |
|
4- 32 |
4- 32 |
4- 32 |
4- 32 |
Vdc |
| Control current range |
|
8-30 |
8-30 |
8-30 |
8-30 |
mA |
| Pick-up voltage |
|
4-0 |
4-0 |
4-0 |
4-0 |
Vdc |
| Drop-out voltage |
|
1-0 |
1-0 |
1-0 |
1-0 |
Vdc |
| Input resistance |
|
Current regulator |
|
| OUTPUT |
| Mains control voltage |
VRMS |
50-480 |
50-480 |
50-480 |
50-480 |
Vac |
| Repetitive peak off state voltage |
VDRM |
800 |
800 |
800 |
800 |
Vpk |
| RMS on-state current |
IT |
10 |
16 |
25 |
40 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| On-state voltage drop |
VTM |
1.6 |
1.6 |
1.6 |
1.6 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
10 |
10 |
10 |
10 |
mA |
| Peak one cycle surge current (non-rep) |
ITSM |
100 |
160 |
500 |
500 |
A |
| Holding current |
IH |
50 |
70 |
120 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
200 |
200 |
200 |
200 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
2 |
1.6 |
1 |
0.85 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Operating temperature |
TO |
-30 to +80 |
-30 to +80 |
-30 to +80 |
-30 to +80 |
°C |
| Turn-on time |
T-on |
10 |
10 |
10 |
10 |
ms |
| Turn-off time |
T-off |
10 |
10 |
10 |
10 |
ms |
| Fusing current |
I2t |
50 |
128 |
1250 |
1250 |
A2s |
Single Phase Solid State Relays Series: 1 SJ/K |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
| DC CONTROL |
| Control voltage range |
|
180- 280 |
180- 280 |
180- 280 |
180- 280 |
Vac |
| Control current range |
|
9-18 |
9-18 |
9-189-18 |
9-18 |
mA |
| Pick-up voltage |
|
180 |
180 |
180 |
180 |
Vac |
| Drop-out voltage |
|
45 |
45 |
45 |
45 |
Vac |
| Input resistance |
|
Current regulator |
|
| OUTPUT |
| Mains control voltage |
VRMS |
50-480 |
50-480 |
50-480 |
50-480 |
Vac |
| Repetitive peak off state voltage |
VDRM |
800 |
800 |
800 |
800 |
Vpk |
| RMS on-state current |
IT |
10 |
16 |
25 |
40 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| On-state voltage drop |
VTM |
1.6 |
1.6 |
1.6 |
1.6 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
10 |
10 |
10 |
10 |
mA |
| Peak one cycle surge current (non-rep) |
ITSM |
100 |
160 |
500 |
500 |
A |
| Holding current |
IH |
50 |
70 |
120 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
200 |
200 |
200 |
200 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
2 |
1.6 |
1 |
0.85 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Operating temperature |
TO |
-30 to +80 |
-30 to +80 |
-30 to +80 |
-30 to +80 |
°C |
| Turn-on time |
T-on |
40 |
40 |
40 |
40 |
ms |
| Turn-off time |
T-off |
80 |
80 |
80 |
80 |
ms |
| Fusing current |
I2t |
50 |
128 |
1250 |
1250 |
A2s |
Single Phase Solid State Relays Series: 20 SJ/K |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
|
|
|
| DC CONTROL |
| Control voltage range |
|
4- 32 |
4- 32 |
4- 32 |
4- 32 |
Vdc |
| Control current range |
|
8-30 |
8-30 |
8-30 |
8-30 |
mA |
| Pick-up voltage |
|
4-0 |
4-0 |
4-0 |
4-0 |
Vdc |
| Drop-out voltage |
|
1-0 |
1-0 |
1-0 |
1-0 |
Vdc |
| Input resistance |
|
Current regulator |
|
| OUTPUT |
| Mains control voltage |
VRMS |
100-480 |
100-480 |
100-480 |
100-480 |
Vac |
| Repetitive peak off state voltage |
VDRM |
1200-1600 |
1200-1600 |
1200-1600 |
1200-1600 |
Vpk |
| RMS on-state current |
IT |
25 |
35 |
75 |
90 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| On-state voltage drop |
VTM |
1.6 |
1.6 |
1.6 |
1.6 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
10 |
10 |
10 |
10 |
mA |
| Peak one cycle surge current (non-rep) |
ITSM |
400 |
500 |
1150 |
1350 |
A |
| Holding current |
IH |
250 |
250 |
250 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
1000 |
1000 |
1000 |
1000 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
1.38 |
0.7 |
0.6 |
0.56 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Operating temperature |
TO |
-30 to +80 |
-30 to +80 |
-30 to +80 |
-30 to +80 |
°C |
| Turn-on time |
T-on |
10 |
10 |
10 |
10 |
ms |
| Turn-off time |
T-off |
10 |
10 |
10 |
10 |
ms |
| Fusing current |
I2t |
600 |
1250 |
5000 |
5000 |
A2s |
Single Phase Solid State Relays Series: 20 SJ/K |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
| DC CONTROL |
| Control voltage range |
|
90- 280 |
90- 280 |
90- 280 |
90- 280 |
Vac |
| Control current range |
|
4-25 |
|
|
|
mA |
| Pick-up voltage |
|
90 |
90 |
90 |
90 |
Vac |
| Drop-out voltage |
|
10 |
10 |
10 |
10 |
Vac |
| Input resistance |
|
Current regulator |
|
| OUTPUT |
| Mains control voltage |
VRMS |
100-480 |
100-480 |
100-480 |
100-480 |
Vac |
| Repetitive peak off state voltage |
VDRM |
1200-1600 |
1200-1600 |
1200-1600 |
1200-1600 |
Vpk |
| RMS on-state current |
IT |
25 |
35 |
75 |
90 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| On-state voltage drop |
VTM |
1.6 |
2 |
2 |
2 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
10 |
10 |
10 |
10 |
mA |
| Peak one cycle surge current (non-rep) |
ITSM |
400 |
500 |
1150 |
1350 |
A |
| Holding current |
IH |
250 |
250 |
250 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
1000 |
1000 |
1000 |
1000 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
1.38 |
0.7 |
0.6 |
0.56 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Operating temperature |
TO |
-30 to +80 |
-30 to +80 |
-30 to +80 |
-30 to +80 |
°C |
| Turn-on time |
T-on |
40 |
40 |
40 |
40 |
ms |
| Turn-off time |
T-off |
40 |
40 |
40 |
40 |
ms |
| Fusing current |
I2t |
600 |
1250 |
5000 |
5000 |
A2s |
Single Phase Solid State Relays Series: 20 SJ/K |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
|
|
|
| DC CONTROL |
| Control voltage range |
|
4-32 |
4-32 |
4-32 |
4-32 |
Vdc |
| Control current range |
|
18-30 |
18-30 |
18-30 |
18-30 |
mA |
| Pick-up voltage |
|
4 |
4 |
4 |
4 |
Vdc |
| Input impedance |
|
Current regulator |
|
| Drop out voltage |
|
1 |
1 |
1 |
1 |
Vdc |
| OUTPUT |
| Main voltage range |
VRMS |
48-660 |
48-660 |
48-660 |
48-660 |
Vac |
| Repetitive peak off state voltage |
VDRM |
1200/1600 |
1200/1600 |
1200/1600 |
1200/1600 |
Vpk |
| Rated Load current |
IT |
125 |
150 |
175 |
205 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
1 |
1 |
1 |
1 |
mA |
| Peak one cycle surge current (non-rep) |
ITSM |
1250 |
1350 |
1500 |
2250 |
A |
| Holding current |
IH |
250 |
250 |
250 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
1000 |
1000 |
1000 |
1000 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
0.35 |
0.35 |
0.25 |
0.1 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Operating temperature |
To |
-25 to +80 |
-25 to +80 |
-25 to +80 |
-25 to +80 |
°C |
| Turn-on time |
T-on |
10 |
10 |
10 |
10 |
ms |
| Turn-off time |
T-off |
10 |
10 |
10 |
10 |
ms |
| Fusing current @ 25°C (8.3ms) |
I2t |
5000 |
8000 |
15000 |
25000 |
A2s |
Single Phase Solid State Relays Series: 20 SJ/K |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
|
|
|
| DC CONTROL |
| Control voltage range |
|
90-280 |
90-280 |
90-280 |
90-280 |
Vac |
| Control current range |
|
4-10 |
4-10 |
4-10 |
4-10 |
mA |
| Pick-up voltage |
|
90 |
90 |
90 |
90 |
Vac |
| Input impedance |
|
25 |
25-26 |
25-26 |
25-26 |
K Ohms |
| Drop out voltage |
|
10 |
10 |
10 |
10 |
Vac |
| OUTPUT |
| Main voltage range |
VRMS |
48-660 |
48-660 |
48-660 |
48-660 |
Vac |
| Repetitive peak off state voltage |
VDRM |
1200/1600 |
1200/1600 |
1200/1600 |
1200/1600 |
Vpk |
| Rated Load current |
IT |
125 |
150 |
175 |
205 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
1 |
1 |
1 |
1 |
mA |
| Peak one cycle surge current (non-rep) |
ITSM |
1250 |
1350 |
1500 |
2250 |
A |
| Holding current |
IH |
250 |
250 |
250 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
1000 |
1000 |
1000 |
1000 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
0.36 |
0.36 |
0.25 |
0.1 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Operating temperature |
To |
-25 to +80 |
-25 to +80 |
-25 to +80 |
-25 to +80 |
°C |
| Turn-on time |
T-on |
40 |
40 |
40 |
40 |
ms |
| Turn-off time |
T-off |
80 |
80 |
80 |
80 |
ms |
| Fusing current @ 25°C (8.3ms) |
I2t |
5000 |
8000 |
15000 |
25000 |
A2s |
Three Phase Solid State Relays Series: 12 SJ/K |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
|
|
|
| AC CONTROL |
| Control voltage range |
|
90-280 |
90-280 |
90-280 |
90-280 |
Vac |
| Control current range |
|
8-80 |
8-80 |
8-80 |
8-80 |
mA |
| Pick-up voltage |
|
90 |
90 |
90 |
90 |
Vac |
| Drop-out voltage I |
|
10 |
10 |
10 |
10 |
Vac |
| nput resistance |
|
Current regulator |
|
| OUTPUT |
| Mains control voltage |
VRMS</div> |
100-660 |
100-660 |
100-660 |
100-660 |
Vac |
| Repetitive peak off state voltage |
VDRM |
800-1600 |
800-1600 |
800-1600 |
800-1600 |
Vpk |
| RMS on-state current |
IT |
25 |
50 |
75 |
90 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| On-state voltage drop |
VTM |
1.6 |
2 |
2 |
2 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
1 |
1 |
1 |
1 |
mA |
| Peak one cycle surge current (non-rep) |
ITSM |
400 |
500 |
1150 |
1150 |
A |
| Holding current |
IH |
250 |
250 |
250 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
1000 |
1000 |
1000 |
1000 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
1.38 |
0.7 |
0.6 |
0.56 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Operating temperature |
TO |
-30 to +80 |
-30 to +80 |
-30 to +80 |
-30 to +80 |
°C |
| Turn-on time |
T-on |
40 |
40 |
40 |
40 |
ms |
| Turn-off time |
T-off |
80 |
80 |
80 |
80 |
ms |
| Fusing current |
I22
|
600 |
1250 |
5000 |
5000 |
A2s |
Three Phase Solid State Relays Series: 12 SJ/K |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
|
|
|
| AC CONTROL |
| Control voltage range |
|
4-32 |
4-32 |
4-32 |
4-32 |
Vdc |
| Control current range |
|
8-80 |
8-80 |
8-80 |
8-80 |
mA |
| Pick-up voltage |
|
4-0 |
4-0 |
4-0 |
4-0 |
Vdc |
| Drop-out voltage I |
|
1-0 |
1-0 |
1-0 |
1-0 |
Vdc |
| Input resistance |
|
Current regulator |
|
| OUTPUT |
|
|
|
|
|
|
| Mains control voltage |
VRMS |
100-660 |
100-660 |
100-660 |
100-660 |
Vac |
| Repetitive peak off state voltage |
VDRM |
800-1600 |
800-1600 |
800-1600 |
800-1600 |
Vpk |
| RMS on-state current |
IT |
25 |
50 |
75 |
90 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| On-state voltage drop |
VTM |
1.8 |
2 |
2 |
2 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
1 |
1 |
1 |
1 |
mA |
| Peak one cycle surge current (non-rep) |
ITSM |
400 |
500 |
1150 |
1150 |
A |
| Holding current |
IH |
250 |
250 |
250 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
1000 |
1000 |
1000 |
1000 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
1.38 |
0.7 |
0.6 |
0.56 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Operating temperature |
TO |
-30 to +80 |
-30 to +80 |
-30 to +80 |
-30 to +80 |
°C |
| Turn-on time |
T-on |
10 |
10 |
10 |
10 |
ms |
| Turn-off time |
T-off |
10 |
10 |
10 |
10 |
ms |
| Fusing current |
I2t |
600 |
1250 |
5000 |
5000 |
A2s |
DIN Ready Solid State Relay |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
|
|
|
| DC CONTROL |
| Control current range |
|
4-32 |
4-32 |
4-32 |
4-32 |
Vdc |
| Control voltage range |
|
|
8-30 |
8-30 |
8-30 |
mA |
| Pick-up voltage |
|
3 |
3 |
3 |
3 |
Vdc |
| Drop-out voltage |
|
1 |
1 |
1 |
|
Vdc |
| Input resistance |
|
Current regulator |
|
| OUTPUT |
| Mains control voltage |
VRMS |
48-660 |
48-660 |
48-660 |
48-660 |
|
| Repetitive peak off state voltage |
VDRM |
1200 |
|
1200 |
1200 |
Vpk Vac |
| RMS on-state current |
IT |
10 |
16 |
25 |
40 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| On-state voltage drop |
VTM |
1.6 |
1.6 |
1.8 |
1.8 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
5 |
5 |
5 |
5 |
mA |
| Peak one cycle surge current (non-Rrep) |
ITSM |
100 |
250 |
1000 |
1000 |
A |
| Holding current |
IH |
75 |
120 |
250 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
200 |
200 |
700 |
700 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
1.8 |
1.3 |
0.43 |
0.43 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Storage temperature |
To |
-30 to +100 |
-30 to +100 |
-30 to +100 |
-30 to +100 |
°C |
| Operating temperature |
TO |
-30 to +80 |
-30 to +80 |
-30 to +80 |
-30 to +80 |
°C |
| Turn-on time |
T-on |
10 |
10 |
10 |
10 |
ms |
| Turn-off time |
T-off |
10 |
10 |
10 |
10 |
ms |
| Fusing current |
I2t |
72 |
128 |
3700 |
5000 |
A2s |
DIN Ready Solid State Relay |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
|
|
|
| DC CONTROL |
| Control current range |
|
90-280 |
90-280 |
90-280 |
90-280 |
Vac |
| Control voltage range |
|
4-25 |
|
|
|
mA |
| Pick-up voltage |
|
90 |
90 |
90 |
90 |
Vac |
| Drop-out voltage |
|
10 |
10 |
10 |
10 |
Vac |
| Input resistance |
|
16-25 |
16-25 |
16-25 |
16-25 |
K |
| OUTPUT |
| Mains control voltage |
VRMS |
48-660 |
48-660 |
48-660 |
48-660 |
Vac |
| Repetitive peak off state voltage |
VDRM |
1200 |
1200 |
1200 |
1200 |
Vpk |
| RMS on-state current |
IT |
10 |
16 |
25 |
40 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| On-state voltage drop |
VTM |
1.6 |
1.6 |
1.8 |
1.8 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
5 |
5 |
5 |
5 |
mA |
| Peak one cycle surge current (non-Rrep) |
ITSM |
100 |
250 |
1000 |
1000 |
A |
| Holding current |
IH |
75 |
120 |
250 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
200 |
200 |
700 |
700 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
1.8 |
1.3 |
0.43 |
0.43 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Storage temperature |
To |
-30 to +100 |
-30 to +100 |
-30 to +100 |
-30 to +100 |
°C |
| Operating temperature |
TO |
-30 to +80 |
-30 to +80 |
-30 to +80 |
-30 to +80 |
°C |
| Turn-on time |
T-on |
40 |
40 |
40 |
40 |
ms |
| Turn-off time |
T-off |
80 |
80 |
80 |
80 |
ms |
| Fusing current |
I2t |
72 |
128 |
3700 |
5000 |
A2s |
DIN Ready Solid State Relay |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
|
|
|
| DC CONTROL |
| Control current range |
|
3-32 |
3-32 |
3-32 |
3-32 |
Vdc |
| Control voltage range |
|
8-30 |
8-30 |
8-30 |
8-30 |
mA |
| Pick-up voltage |
|
3 |
3 |
3 |
3 |
Vdc |
| Drop-out voltage |
|
1 |
1 |
1 |
1 |
Vdc |
| Input resistance |
|
Current regulator |
|
| OUTPUT |
| Mains control voltage |
VRMS |
24-240 |
24-240 |
24-240 |
24-240 |
Vac |
| Repetitive peak off state voltage |
VDRM |
600 |
600 |
600 |
600 |
Vpk |
| RMS on-state current |
IT |
10 |
16 |
25 |
40 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| On-state voltage drop |
VTM |
1.6 |
1.6 |
1.8 |
1.8 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
5 |
5 |
5 |
5 |
mA |
| Peak one cycle surge current (non-Rrep) |
ITSM |
100 |
250 |
800 |
800 |
A |
| Holding current |
IH |
75 |
120 |
250 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
200 |
250 |
500 |
500 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
1.8 |
1.3 |
0.43 |
0.43 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Storage temperature |
To |
-30 to +100 |
-30 to +100 |
-30 to +100 |
-30 to +100 |
°C |
| Operating temperature |
TO |
-30 to +80 |
-30 to +80 |
-30 to +80 |
-30 to +80 |
°C |
| Turn-on time |
T-on |
10 |
10 |
10 |
10 |
ms |
| Turn-off time |
T-off |
10 |
10 |
10 |
10 |
ms |
| Fusing current |
I2t |
72 |
128 |
3700 |
5000 |
A2s |
DIN Ready Solid State Relay |
Parameter |
Symbol |
Type |
Unit |
|
|
|
|
|
|
|
| DC CONTROL |
| Control current range |
|
90-280 |
90-280 |
90-280 |
90-280 |
Vac |
| Control voltage range |
|
4-25 |
4-25 |
4-25 |
4-25 |
mA |
| Pick-up voltage |
|
90 |
90 |
90 |
90 |
Vac |
| Drop-out voltage |
|
10 |
10 |
10 |
10 |
Vac |
| Input resistance |
|
16-25 |
16-25 |
16-25 |
16-25 |
Kohm |
| OUTPUT |
| Mains control voltage |
VRMS |
24-240 |
24-240 |
24-240 |
24-240 |
Vac |
| Repetitive peak off state voltage |
VDRM |
600 |
600 |
600 |
600 |
Vpk |
| RMS on-state current |
IT |
10 |
16 |
25 |
40 |
A |
| Zero turn-on voltage |
|
35 |
35 |
35 |
35 |
Vac |
| On-state voltage drop |
VTM |
1.6 |
1.6 |
1.8 |
1.8 |
Vac |
| Off-state leakage current @ rated voltage |
IDRM |
5 |
5 |
5 |
5 |
mA |
| Peak one cycle surge current (non-Rrep) |
ITSM |
100 |
250 |
1000 |
1000 |
A |
| Holding current |
IH |
75 |
120 |
250 |
250 |
mA |
| Critical rate of rise of off-state voltage |
dv/dt |
200 |
200 |
700 |
700 |
V/μs |
| Thermal resistance (junction to case) |
Rthjc |
1.5 |
1.3 |
0.43 |
0.43 |
K/W |
| Frequency range |
f |
47-63 |
47-63 |
47-63 |
47-63 |
Hz |
| Storage temperature |
To |
-30 to +100 |
-30 to +100 |
-30 to +100 |
-30 to +100 |
°C |
| Operating temperature |
TO |
-30 to +80 |
-30 to +80 |
-30 to +80 |
-30 to +80 |
°C |
| Turn-on time |
T-on |
40 |
40 |
40 |
40 |
ms |
| Turn-off time |
T-off |
80 |
80 |
80 |
80 |
ms |
| Fusing current |
I2t |
72 |
128 |
3700 |
5000 |
A2s |